HDD Failure
Error code:
- 205616 HDD Failure
- 205617 HDD Failure
- 205618 HDD Failure
- 205619 HDD Failure
- 205620 HDD Failure
- 205659 Mirroring HDD (A) failure
- 205660 Mirroring HDD (A) failure
- 205661 Mirroring HDD (A) failure
- 205662 Mirroring HDD (A) failure
- 205663 Mirroring HDD (A) failure
- 205679 Mirroring HDD (A) failure
- 205680 Mirroring HDD (B) failure
- 205681 Mirroring HDD (B) failure
- 205682 Mirroring HDD (B) failure
- 205683 Mirroring HDD (B) failure
Occurrence condition
HDD failed (Each error code is the number for analysis)
Mirroring HDD(A) failed (Each error code is the number for analysis)
Mirroring HDD(B) failed (Each error code is the number for analysis)
Assumed cause
- HDD Cable Failure
- HDD Failure
- RAID Board Unit Failure (Mirroring)
- Main Board circuit failure
Related parts
- HDD Unit
- HDD Cable
- Main Board
- Replace the RAID Board Unit (Mirroring)
Troubleshooting
| Step | Confirmation and action | YES | NO |
|---|---|---|---|
| 1 | Check the cable status of HDD unit
|
Go to step 2 | Replacement of HDD cable. |
| 2 | Check the HDD unit connection
|
Go to step 3 | End |
| 3 | Replace the HDD unit
|
Replace the Main Board (Non-Mirroring) Go to step4 (Mirroring) |
End (Non-Mirroring) |
| 4 | Replace the RAID Board Unit
|
Replace the Main Board (Mirroring) | End (Mirroring) |