Cover Open, Maintenance Box
Detection condition
- The Maintenance box cover is open.
Defect-related parts
- Maintenance Box Cover Sensor
- Maintenance Box Cover
- Harness
- Mechanical control board
Troubleshooting
| Step | Confirmation and action | YES | NO |
|---|---|---|---|
| 1 | Check the state of Maintenance Box Cover
|
Go to step 2 | Close the cover correctly |
| 2 | Check the shape of Maintenance Box Cover
|
Replace the Maintenance Box Cover. | Go to step 3 |
| 3 | Check the operation of the Maintenance Box Cover Sensor
|
Replace the mechanical control board |
Go to step 4 |
| 4 | Attach sensor and check connector connection
|
Fully insert the connectors. | Replace the sensor. |