SCN board connection error
Error code: 100048
Occurrence condition
- When communication between the SCN board and main board (Main Unit) is not possible
- When communication between the SCN board and ADF board is not possible
Assumed cause
Poor connection between the SCN Board and the Main Board of Main Unit (cable disconnection / breakage)
Poor connection between the SCN Board and the ADF Board of Main Unit (cable disconnection / breakage)
SCN Unit failure (SCN Board failure)
- ADF Unit failure (ADF Board failure)
Main Board failure
- Power supply Unit failure
- MCU Board failure
Related parts
- SCN Board
- ADF Board
- Main Board (Main Unit)
- SCN Unit
- ADF Unit
- Cables between the Scanner Board and the Main Board (Main Unit)
- Cables between the Scanner Board and the ADF Board
- Power supply Unit
- MCU Board
Troubleshooting
Step |
Confirmation and action |
Yes |
No |
|---|---|---|---|
1 |
Check cable connection status
|
Go to step 2 |
Reconnect cable or replace cable |
| 2 | Check by replacing ADF Unit
|
Go to step 3 | Replace the ADF Unit |
| 3 | Check by replacing SCN Unit
|
Replace the following parts.
|
Replace the SCN Unit |