FIN Finisher Tray error 1

Error code
  • 035006 FIN Finisher Tray error 1
Occurrence condition
  • FIN Finisher Tray Upper Limit Sensor, FIN Finisher Tray HP Sensor, and FIN Finisher Tray Upper Sensor do not turn ON even after 30 seconds have passed when the FIN Finisher Tray is raised.
Assumed cause
  • Deformation, dropout, or failure of IN FIN Finisher Tray
  • Deformation, dropout, or failure of IN FIN Finisher Tray Drive Parts
  • FIN Finisher Tray Elevating Motor dirty, missing or defective
  • FIN Finisher Tray Upper Limit Sensor dirty, missing or defective
  • FIN Finisher Tray HP Sensor dirty, missing or defective
  • FIN Finisher Tray Upper Sensor dirty, missing or defective
  • Floor Finisher main board failure
Related parts
  • FIN Finisher Tray
  • FIN Finisher Tray Drive Parts
  • FIN Main Tray Rise/Fall Motor
  • FIN Finisher Tray Upper Limit Sensor
  • FIN Finisher Tray HP Sensor
  • FIN Finisher Tray Upper Sensor
  • Floor Finisher Main Board
Troubleshooting
Step Confirmation and action YES NO
1

Check the FIN Finisher Tray

  • Is the FIN Finisher Tray assembled correctly?
Go to step 2 If the FIN Finisher Tray cannot be moved manually, fix the part where it is stuck.
2

Check the FIN Finisher Tray Drive Parts

  • Is the FIN Finisher Tray Drive Parts installed properly?
  • Are there any problems with the drive parts?
Go to step 3

Reinstall the FIN Finisher Tray Drive Parts

Replace if not repaired

3

Check the FIN Finisher Tray Elevating Motor

[Part(s) to be checked]

  • FIN Finisher Tray Elevating Motor - Floor Finisher Main Board

[Confirmation details]

  • Is the FIN Finisher Tray Elevating Motor missing or improperly installed?
  • Is there any abnormality (damage/wear) in the FIN Finisher Tray Elevating Motor?
  • Are the connectors connected properly?
  • Are there any problems with the wires?
Go to step 4

In case of falling off or improper installation

  • Check the operation of the FIN Finisher Tray Elevating Motor

If there is an abnormality (damage/wear)

  • Replace the FIN Finisher Tray Elevating Motor

Improper connector connection

  • Clean the wire connector and reinsert it.

If the wire is abnormal

  • Replace the wire.
4

Check the operation of the FIN Finisher Tray Elevating Motor

Are the following motors operating normally in Failure Verification menu?

  • FIN Finisher Tray Elevating Motor
Go to step 5 Replace the FIN Finisher Tray Elevating Motor
5

Check the FIN Finisher Tray related sensors

[Part(s) to be checked]

  • FIN Finisher Tray Upper Limit Sensor - Floor Finisher Main Board
  • FIN Finisher Tray HP Sensor - Floor Finisher Main Board
  • FIN Finisher Tray Upper Sensor - Floor Finisher Main Board

[Confirmation details]

  • Are there any missing parts or improper installation?
  • Are there any abnormalities (damage/wear) in the relevant locations?
  • Are the connectors connected properly?
  • Are there any problems with the wires?
Go to step 6

In case of falling off or improper installation

  • Reassembly of applicable sensors

If there is an abnormality (damage/wear)

  • Replace applicable sensor

Improper connector connection

  • Clean the wire connector and reinsert it.

If the wire is abnormal

  • Replace the wire.
6

Check the operation of the FIN Finisher Tray related sensors

Are the following sensor operating normally in Failure Verification menu?

  • FIN Finisher Tray Upper Limit Sensor
  • FIN Finisher Tray HP Sensor
  • FIN Finisher Tray Upper Sensor
Go to step 7 Replace the corresponding sensor
9

Replacing floor finisher main board

  • Replaced the floor finisher main board, did the phenomenon improve?
End Contact Epson local service representatives.