SDL Feed Tray Motor error

Error code
  • 035320 SDL Feed Tray Motor error
Occurrence condition
  • A lock signal was detected for 0.1 second after the specified time had passed since the SDL Feed Tray Motor was started.
Assumed cause
  • Dirty, missing, or defective SDL Feed Tray Motor
  • SDL Unit Main Board failure
Related parts
  • SDL Feed Tray Motor
  • SDL Unit Main Board
Troubleshooting

Step

Confirmation and action

YES

NO

1

Check the SDL Feed Tray Motor

[Part(s) to be checked]

  • SDL Feed Tray Motor - SDL Unit Main Board

[Confirmation details]

  • Is the SDL Feed Tray Motor missing or improperly installed?
  • Is there any abnormality (damage/wear) in the SDL Feed Tray Motor?
  • Are the connectors connected properly?
  • Are there any problems with the wires?
Go to step 2

In case of falling off or improper installation

  • Reassembly of the SDL Feed Tray Motor

If there is an abnormality (damage/wear)

  • Replace the SDL Feed Tray Motor

Improper connector connection

  • Clean the wire connector and reinsert it.

If the wire is abnormal

  • Replace the wire
2

Check the operation of the SDL Feed Tray Motor

Are the following motors operating normally in Failure Verification menu?

  • SDL Feed Tray Motor
Go to step 3 Replace the SDL Feed Tray Motor
3

Replace SDL Unit Main Board

  • Replaced the SDL Unit Main Board and did the problem improve?
End Contact Epson local service representatives