Cover open, Multi-Cassette Cover

Detection condition
  • Multi-Cassette Feed Cover Assy is open
Defect-related parts
  • Multi-Cassette Cover Sensor
  • Multi-Cassette Feed Cover Assy
  • Harness
  • Mechanical control board
Troubleshooting
Step Confirmation and action YES NO
1

Check status of the Multi-Cassette Feed Cover Assy

  • Is the Multi-Cassette Feed Cover Assy closed correctly?
Go to step 2 Close the Multi-Cassette Feed Cover Assy correctly
2

Check shape of the Multi-Cassette Feed Cover Assy

  • Check the shape of the part that presses the Front Cover Sensor. Is there any deformation or damage on the corresponding part?
Replace the Multi-Cassette Feed Cover Assy Go to step 3
3

Check the operation of the Multi-Cassette Cover Sensor
Check the sensor operation using the diagnostic function.

  • Judgment: Does the signal change by opening/closing the cover?

Replace the mechanical control board

Go to step 4
4

Attach sensor and check connector connection

  • Is there any abnormality in the Front Cover Sensor or half-inserted in the connector?
Fully insert the connectors.

Replace the sensor.