SDL Transport Motor Jam (Feed delay)
Error code
- 119 SDL Paper Transport Unreached Jam (Feed delay)
Occurrence condition
- The SDL Transport sensor does not turn on even after the specified time has passed since the SDL Vertical Paper Feed Sensor turned on.
Assumed cause
- Rollers, guides, etc. are dirty, deformed, or not installed properly
- Damaged or malfunctioning SDL Transport sensor
- Dirty, missing, or defective SDL Paper Transport Motor
- Failure of the SDL Unit Main Board
- Floor Finisher main board failure
Related parts
- SDL Paper Transport Sensor
- SDL Paper Transport Motor
- SDL Unit Main Board
- Floor Finisher Main Board
Troubleshooting
Step |
Confirmation and action |
YES |
NO |
|---|---|---|---|
| 1 | Check paper transport path Is there any foreign matter, paper chips, etc. in the paper transport path? |
Remove any foreign objects or pieces of paper |
Go to step 2 |
| 2 | SDL Transport SensorCheck the connection of the connector Is the SDL Transport sensor properly connected? |
Go to step 3 | reconnect SDL Transport sensor |
| 3 | SDL Transport SensorOperation Check Is the SDL Transport sensor operating normally in the diagnostics menu? |
Go to step 4 | replace SDL Transport sensor |
| 4 | SDL Paper Transport MotorCheck the connection of the connector Are the SDL Paper Transport Motor connected properly? |
Go to step 5 | reconnect SDL Paper Transport Motor |
| 5 | SDL Paper Transport MotorOperation Check Is the SDL Paper Transport Motor operating normally in the diagnostics menu? |
Go to step 6 | Replace SDL Paper Transport Motor |
| 6 | Replace SDL Unit Main Board Have you reconnected and repaired the connector on the SDL unit main board? |
Go to step 7 | Replace the SDL Unit Main Board |
| 7 | Replacing floor finisher main board Have you reconnected and repaired the connector on the floor finisher main board? |
End | Replace floor finisher main board |