PCIMGR access right gain/return error

Error code
  • 032519  PCIMGR access right gain failure error
  • 032520  PCIMGR access right return error
Occurrence condition
  • Poor connection between the Main Board and the Head Unit (cable disconnected/inserted loosely/slanted, etc.)

  • Poor connection between the MCU Board and the Head Unit (cable disconnected/inserted loosely/slanted, etc.)
  • Damage to the Main Board

  • Damage to the MCU Board
  • Damage to the Power Supply Board
  • Damage to the Head control Board

Defect-related parts
  • Head USB Cable
  • Head connection Harness
  • Head Unit
  • Main Board
  • MCU Board
  • Power Supply Box
Troubleshooting
Step Confirmation and action YES NO
1

Check the Head USB cable/Harness connection

Make sure the Head USB cable/Harness is connected correctly.

Does the error persist?

Go to step 2 End
2

Replace the Head USB cable/Harness

Does the error persist?

Go to step 3 End
3

Replacement of Head Unit

Does the error persist?

Go to step 4 End
4

Replacement of the Main Board

Does the error persist?
Go to step 5 End
5

Replacement of the MCU Board

Does the error persist?
Go to step 6 End
6

Replacement of the Power Supply Box

Does the error persist?
Contact Epson local service representatives. End