FIN Shift Arm Motor Rear error

Error code
  • 035004 FIN Shift Arm Motor Rear error
Occurrence condition
  • When FIN Shift Arm Motor Rear is driven, FIN Rear Shift Arm HP Sensor does not turn ON even after moving 160 mm.
Assumed cause
  • Deformation, dropout, or failure of FIN Shift Arm Rear
  • Deformation, dropout, or failure of FIN Shift Arm Rear Drive Parts
  • FIN Shift Arm Motor Rear dirty, missing or defective
  • FIN Rear Shift Arm HP Sensor dirty, missing or defective.
  • Floor Finisher main board failure
Related parts
  • FIN Shift Arm Rear
  • FIN Shift Arm Rear Drive Parts
  • FIN After Width Alignment Shift Arm Motor
  • FIN Rear Shift Arm HP Sensor
  • Floor Finisher Main Board
Troubleshooting
Step Confirmation and action YES NO
1

Check the FIN Shift Arm Rear

  • Is the FIN Shift Arm Rear assembled correctly?
Go to step 2 If the FIN Shift Arm Rear cannot be moved manually, fix the part where it is stuck.
2

Check the FIN Shift Arm Rear Drive Parts

  • Is the FIN Shift Arm Rear Drive Parts installed properly?
  • Are there any problems with the drive parts?
Go to step 3

Reinstall the FIN Shift Arm Rear Drive Parts

Replace if not repaired

3

Check the FIN After Width Alignment Shift Arm Motor

[Part(s) to be checked]

  • FIN After Width Alignment Shift Arm Motor - Floor Finisher Main Board

[Confirmation details]

  • Is the FIN After Width Alignment Shift Arm Motor missing or improperly installed?
  • Is there any abnormality (damage/wear) in the FIN After Width Alignment Shift Arm Motor?
  • Are the connectors connected properly?
  • Are there any problems with the wires?
Go to step 4

In case of falling off or improper installation

  • Reassembly of the FIN After Width Alignment Shift Arm Motor

If there is an abnormality (damage/wear)

  • Replace the FIN After Width Alignment Shift Arm Motor

Improper connector connection

  • Clean the wire connector and reinsert it.

If the wire is abnormal

  • Replace the wire.
4

Check the operation of the FIN After Width Alignment Shift Arm Motor

Are the following motors operating normally in Failure Verification menu?

  • FIN After Width Alignment Shift Arm Motor
Go to step 5 Replace the FIN After Width Alignment Shift Arm Motor
5

Check the FIN Rear Shift Arm HP Sensor

[Part(s) to be checked]

  • FIN Rear Shift Arm HP Sensor - Floor Finisher Main Board

[Confirmation details]

  • Is the FIN Rear Shift Arm HP Sensor missing or improperly installed?
  • Is there any abnormality (damage/wear) in the FIN Rear Shift Arm HP Sensor?
  • Are the connectors connected properly?
  • Are there any problems with the wires?
Go to step 6

In case of falling off or improper installation

  • Reassembly of the FIN Rear Shift Arm HP Sensor

If there is an abnormality (damage/wear)

  • Replace the FIN Rear Shift Arm HP Sensor

Improper connector connection

  • Clean the wire connector and reinsert it.

If the wire is abnormal

  • Replace the wire.
6

Check the operation of the FIN Rear Shift Arm HP Sensor

Are the following sensor operating normally in Failure Verification menu?

  • FIN Rear Shift Arm HP Sensor
Go to step 7 Replace the FIN Rear Shift Arm HP Sensor
7

Replacing floor finisher main board

  • Replaced the floor finisher main board, did the phenomenon improve?
End Contact Epson local service representatives.