FIN Bundle Eject Unit Drive Motor error
Error code
- 035002 FIN Bundle Eject Unit Drive Motor error
Occurrence condition
- When the FIN Bundle Eject Unit Drive Motor is running, the FIN Bundle Ejection Unit HP Sensor does not turn on even after 1 second has passed.
- Even if the FIN Bundle Eject Unit Drive Motor is driven for 1 second after the FIN Bundle Ejection Unit HP Sensor is ON, the FIN Bundle Ejection Unit HP Sensor does not turn off.
Assumed cause
- FIN Bundle Eject Unit dirty, falling off, or malfunctioning
- FIN Bundle Eject Unit Drive Parts dirty, missing or defective
- FIN Bundle Eject Unit Drive Motor dirty, missing or defective
- FIN Bundle Eject Unit HP Sensor dirty, missing or defective
- Floor Finisher main board failure
Related parts
- FIN Bundle Eject Unit
- FIN Bundle Eject Unit Drive Parts
- FIN Bundle Eject Unit Drive Motor
- FIN Bundle Ejection Unit HP Sensor
- Floor Finisher Main Board
Troubleshooting
| Step | Confirmation and action | YES | NO |
|---|---|---|---|
| 1 | Check the FIN Bundle Eject Unit
|
Modify FIN Bundle Eject Unit | Go to step 2 |
| 2 | Check the FIN Bundle Eject Unit Drive Motor
|
Go to step 3 | Reinstall FIN Bundle Eject Unit Drive Parts Replace if not repaired |
| 3 | Check the connection of the FIN Bundle Eject Unit Drive Motor [Part(s) to be checked]
[Confirmation details]
|
Go to step 4 | In case of falling off or improper installation
If there is an abnormality (damage/wear)
Improper connector connection
If the wire is abnormal
|
| 4 | Check the operation of the FIN Bundle Eject Unit Drive Motor Are the following motors operating normally in Failure Verification menu?
|
Go to step 5 | Replace the FIN Bundle Eject Unit Drive Motor |
| 5 | Check the FIN Bundle Ejection Unit HP Sensor [Part(s) to be checked]
[Confirmation details]
|
Go to step 6 | In case of falling off or improper installation
If there is an abnormality (damage/wear)
Improper connector connection
If the wire is abnormal
|
| 6 | Check the operation of the FIN Bundle Ejection Unit HP Sensor Are the following sensor operating normally in Failure Verification menu?
|
Go to step 7 | Replace the FIN Bundle Ejection Unit HP Sensor |
| 7 | Replacing floor finisher main board
|
End | Contact Epson local service representatives. |