FIN Bundle Eject Unit Drive Motor error

Error code
  • 035002 FIN Bundle Eject Unit Drive Motor error
Occurrence condition
  • When the FIN Bundle Eject Unit Drive Motor is running, the FIN Bundle Ejection Unit HP Sensor does not turn on even after 1 second has passed.
  • Even if the FIN Bundle Eject Unit Drive Motor is driven for 1 second after the FIN Bundle Ejection Unit HP Sensor is ON, the FIN Bundle Ejection Unit HP Sensor does not turn off.
Assumed cause
  • FIN Bundle Eject Unit dirty, falling off, or malfunctioning
  • FIN Bundle Eject Unit Drive Parts dirty, missing or defective
  • FIN Bundle Eject Unit Drive Motor dirty, missing or defective
  • FIN Bundle Eject Unit HP Sensor dirty, missing or defective
  • Floor Finisher main board failure
Related parts
  • FIN Bundle Eject Unit
  • FIN Bundle Eject Unit Drive Parts
  • FIN Bundle Eject Unit Drive Motor
  • FIN Bundle Ejection Unit HP Sensor
  • Floor Finisher Main Board
Troubleshooting
Step Confirmation and action YES NO
1

Check the FIN Bundle Eject Unit

  • Are parts such as the ejection guide of the FIN Bundle Eject Unit deformed?
Modify FIN Bundle Eject Unit Go to step 2
2

Check the FIN Bundle Eject Unit Drive Motor

  • Is the FIN Bundle Eject Unit Drive Parts installed properly?
  • Are there any problems with the drive parts?
Go to step 3

Reinstall FIN Bundle Eject Unit Drive Parts

Replace if not repaired

3

Check the connection of the FIN Bundle Eject Unit Drive Motor

[Part(s) to be checked]

  • FIN Bundle Eject Unit Drive Motor - Floor Finisher Main Board

[Confirmation details]

  • Is the FIN Bundle Eject Unit Drive Motor missing or improperly installed?
  • Is there any abnormality (damage/wear) in the FIN Bundle Eject Unit Drive Motor?
  • Are the connectors connected properly?
  • Are there any problems with the wires?
Go to step 4

In case of falling off or improper installation

  • Reassembly of the FIN Bundle Eject Unit Drive Motor

If there is an abnormality (damage/wear)

  • Replace the FIN Bundle Eject Unit Drive Motor

Improper connector connection

  • Clean the wire connector and reinsert it.

If the wire is abnormal

  • Replace the wire.
4

Check the operation of the FIN Bundle Eject Unit Drive Motor

Are the following motors operating normally in Failure Verification menu?

  • FIN Bundle Eject Unit Drive Motor
Go to step 5 Replace the FIN Bundle Eject Unit Drive Motor
5

Check the FIN Bundle Ejection Unit HP Sensor

[Part(s) to be checked]

  • FIN Bundle Ejection Unit HP Sensor - Floor Finisher Main Board

[Confirmation details]

  • Is the FIN Bundle Ejection Unit HP Sensor missing or improperly installed?
  • Is there any abnormality (damage/wear) in the FIN Bundle Ejection Unit HP Sensor?
  • Are the connectors connected properly?
  • Are there any problems with the wires?
Go to step 6

In case of falling off or improper installation

  • Reassembly of the FIN Bundle Ejection Unit HP Sensor

If there is an abnormality (damage/wear)

  • Replace the FIN Bundle Ejection Unit HP Sensor

Improper connector connection

  • Clean the wire connector and reinsert it.

If the wire is abnormal

  • Replace the wire.
6

Check the operation of the FIN Bundle Ejection Unit HP Sensor

Are the following sensor operating normally in Failure Verification menu?

  • FIN Bundle Ejection Unit HP Sensor
Go to step 7 Replace the FIN Bundle Ejection Unit HP Sensor
7

Replacing floor finisher main board

  • Replaced the floor finisher main board, did the phenomenon improve?
End Contact Epson local service representatives.