SDL Alignment Plate Lower HP Sensor Jam
Error code
- 126 SDL Alignment Plate Lower HP Sensor Jam
Occurrence condition
- After moving under the SDL Alignment Plate Low to SDL Alignment Plate Lower HP Sensor, the ON sensor is not detected even after the specified time has passed.
Assumed cause
- SDL Alignment Plate Lower is not installed properly
- Broken or malfunctioning SDL Alignment Plate Lower HP Sensor
- SDL Alignment Motor Lower falling off or malfunctioning
- Failure of the SDL Unit Main Board
- Floor Finisher main board failure
Related parts
- SDL Alignment Plate Lower
- SDL Alignment Plate Lower HP Sensor
- SDL Alignment Motor Lower
- SDL Unit Main Board
- Floor Finisher Main Board
Troubleshooting
Step |
Confirmation and action |
YES |
NO |
|---|---|---|---|
| 1 | Check SDL Alignment Plate Lower Manually check if the SDL Alignment Plate Lower moves and is it smooth? |
Go to step 2 |
Reinstall the SDL Alignment Plate Lower |
| 2 | SDL Alignment Plate Lower HP SensorCheck the connection of the connector Is the SDL Alignment Plate Lower HP Sensor connected properly? |
Go to step 3 | Reconnect the SDL Alignment Plate Lower HP Sensor |
| 3 | SDL Alignment Plate Lower HP SensorOperation Check Is the SDL Alignment Plate Lower HP Sensor operating normally in the diagnostics menu? |
Go to step 4 | Replace the SDL Alignment Plate Lower HP Sensor |
| 4 | SDL Alignment Motor LowerCheck the connection of the connector Is the SDL Alignment Motor Lower properly connected? |
Go to step 5 | reconnect SDL Alignment Motor Lower |
| 5 | SDL Alignment Motor LowerOperation Check Is the SDL Alignment test working properly in the diagnostics menu? |
Go to step 6 | Replace SDL Alignment Motor Lower |
| 6 | Replace SDL Unit Main Board Have you reconnected and repaired the connector on the SDL unit main board? |
Go to step 7 | Replace the SDL Unit Main Board |
| 7 | Replacing floor finisher main board Have you reconnected and repaired the connector on the floor finisher main board? |
End | Replace floor finisher main board |