SCN board overvoltage error
Error code
- 190017 SCN board overvoltage error
Occurrence condition
- The Main Board detected a power circuit failure on the SCN Board.
Assumed cause
- SCN Board failure
- Failure of the harness (SCN-M-SCN 20-pin)
- Main Board failure
- SUB_M Board failure
Related parts
SCN Board
20-pin harness connecting the SUB_M Board and SCN Board
Main Board
SUB_M Board
SCN Unit
Troubleshooting
Step |
Confirmation and action |
Yes |
No |
|---|---|---|---|
1 |
Replace the SCN Board Does the error still occur after replacing the SCN Board? |
Go to step 2 | Replace the SCN Board |
| 2 | Replace the harness
|
Go to step 3 | Replace the harness |
| 3 | Replace the Main Board Does the error still occur after replacing the Main Board? |
Go to step 3 | Replace the Main Board |
| 4 | Replace the SUB_M Board Does the error still occur after replacing the SUB_M Board? |
Replace the SCN Unit | Replace the SUB_M Board |