ADF board overvoltage error
Error code
- 190016 ADF board overvoltage error
Occurrence condition
- The Main Board detected a power circuit failure on the ADF Board.
Assumed cause
ADF Board failure
Failure of the harness (SCN-ADF 22-pin/SUB_M-SCN 20-pin)
SCN Board failure
Main Board failure
SUB_M Board failure
Related parts
ADF Board
22-pin harness connecting the SCN Board and ADF Board
20-pin harness connecting the SUB_M Board and SCN Board
SCN Board
Main Board
SUB_M Board
ADF Unit
Troubleshooting
Step |
Confirmation and action |
Yes |
No |
|---|---|---|---|
1 |
Replace the ADF Board Does the error still occur after replacing the ADF Board? |
Go to step 2 | Replace the ADF Board |
| 2 | Replace the harness
|
Go to step 3 | Replace the harness |
| 3 | Replace the SCN Board Does the error still occur after replacing the SCN Board? |
Go to step 4 | Replace the SCN Board |
| 4 | Replace the Main Board Does the error still occur after replacing the Main Board? |
Go to step 5 | Replace the Main Board |
| 5 | Replace the SUB_M Board Does the error still occur after replacing the SUB_M Board? |
Replace the ADF Unit | Replace the SUB_M Board |