Inclination Sensor - After replacement (Only for AM-C6000/C5000/C4000)

Check Point / チェックポイント

When this menu is executed, the following menu is automatically executed.

Program No. Menu Name
60118 Tilt Sensor Adjustment


  1. Turn the power ON.
  2. Press [Execution].
  3. Press [OK].
  4. Open the front cover, remove the ink cartridge (BK), and check the correction value label.
  5. Input the correction values of X, Y, Z and press [OK].
  6. Press [OK] to complete the menu.