PNC Punch Drive Motor Error
Error code
- 035205 PNC Punch Drive Motor Error
Occurrence condition
- When PNC Punch Drive Motor is driven, PNC cam HP sensor does not turn ON even after the specified time has passed.
- The specified number of pulses has not been counted on the pulse plate even after the specified time has passed since the punching operation started.
Assumed cause
- Trouble with FW
- Deformation, dropout, or failure of the floor punch unit
- Dirty, missing or broken PNC cam drive parts
- Dirty, missing or broken IN PNC Punch Motor
- Dirty, missing or broken PNC cam HP Sensor
- Floor punch unit main board failure
- Floor Finisher main board failure
Related parts
- Floor Punch Unit
- PNC cam drive parts
- PNC Punch Drive Motor
- PNC Cam HP Sensor
- Floor punch unit main board
- Floor Finisher Main Board
Troubleshooting
Step |
Confirmation and action |
YES |
NO |
|---|---|---|---|
| 1 | Perform FW update.
|
End | Go to step 2 |
| 2 | Check the Floor Punch Unit
|
Go to step 3 | Reinstall the Floor Punch Unit |
| 3 | Checking the PNC cam drive parts
|
Go to step 4 | Reinstall the PNC cam drive parts Replace if not repaired |
| 4 | Check connection [Part(s) to be checked]
[Confirmation details]
|
Go to step 5 | In case of falling off or improper installation
If there is an abnormality (damage/wear)
Improper connector connection
If the wire is abnormal
|
| 5 | Check the PNC Punch Drive Motor operation Are the following motors operating normally in Failure Verification menu?
|
Go to step 6 | Replace PNC Punch Drive Motor |
| 6 | Check the PNC Cam HP Sensor operation Are the following sensor operating normally in Failure Verification menu?
|
Go to step 7 | Replace PNC Cam HP Sensor |
| 7 | Replace the Floor punch unit main board
|
End | Go to step 8 |
| 8 | Replacing floor finisher main board
|
End | Contact Epson local service representatives. |