NVT check ID error
Error code
- 031200 NVT nozzle rank check ID error 0
- 031201 NVT nozzle rank check ID error 1
- 031202 NVT nozzle rank check ID error 2
- 031203 NVT nozzle rank check ID error 3
- 031204 NVT nozzle rank check ID error 4
- 031205 NVT nozzle rank check ID error 5
- 031260 NVT nozzle rank check mode value ID error 0
- 031261 NVT nozzle rank check mode value ID error 1
- 031262 NVT nozzle rank check mode value ID error 2
- 031263 NVT nozzle rank check mode value ID error 3
- 031264 NVT nozzle rank check mode value ID error 4
- 031265 NVT nozzle rank check mode value ID error 5
- 031320 NVT mode value rank nozzles count check ID error 0
- 031321 NVT mode value rank nozzles count check ID error 1
- 031322 NVT mode value rank nozzles count check ID error 2
- 031323 NVT mode value rank nozzles count check ID error 3
- 031324 NVT mode value rank nozzles count check ID error 4
- 031325 NVT mode value rank nozzles count check ID error 5
- 031480 NVT Initial Mode Check ID Error 0
- 031481 NVT Initial Mode Check ID Error 1
- 031482 NVT Initial Mode Check ID Error 2
- 031483 NVT Initial Mode Check ID Error 3
- 031484 NVT Initial Mode Check ID Error 4
- 031485 NVT Initial Mode Check ID Error 5
Occurrence condition
- When reading memory information in Head replacement, Check ID is mismatching between the calculated value from each reading data and the reading value from the memory.
Assumed cause
- Noise occurred when reading memory information or communication failed.
- Head Unit failure
- Main Board failure
Related parts
- Head Unit
- Main Board
Troubleshooting
| Step | Confirmation and action | YES | NO |
|---|---|---|---|
| 1 | Noise check during data transfer Does the error occur again even if the data is transferred again? |
Go to step 2 |
End |
| 2 | Replace the Head Unit
|
Go to step 3 | End |
| 3 | Replacement of Main Board
|