IN PNC Punch Motor 3
Error code
- 035502 IN PNC Punch Motor 3
Occurrence condition
- When the home position is initialized, it does not turn off from the home position ON position within 0.05 seconds.
Assumed cause
- Trouble with FW
- Deformation, dropout, or failure of the inner punch unit
- Dirty, missing or broken IN PNC cam drive parts
- Dirty, missing or broken IN PNC Punch Motor
- Inner punch unit main board failure
- Inner Finisher main board failure
Related parts
- Inner Punch Unit
- IN PNC cam drive parts
- IN PNC Punch Motor
- Inner Punch Unit Main Board
- Inner Finisher Main Board
Troubleshooting
Step |
Confirmation and action |
YES |
NO |
|---|---|---|---|
| 1 | Perform FW update.
|
End | Go to step 2 |
| 2 | Checking the inner punch unit
|
Go to step 3 | Reinstall Inner Punch Unit |
| 3 | Checking the IN PNC cam drive parts
|
Go to step 4 | Reinstall the IN PNC cam drive parts Replace if not repaired |
| 4 | Check connection [Part(s) to be checked]
[Confirmation details]
|
Go to step 5 | In case of falling off or improper installation
If there is an abnormality (damage/wear)
Improper connector connection
If the wire is abnormal
|
| 5 | Check the IN PNC Punch Motor operation Are the following motors operating normally in Failure Verification menu?
|
Go to step 6 | Replace the IN PNC Punch Motor |
| 6 | Replace the Inner Punch Unit Main Board
|
End | Go to step 7 |
| 7 | Replacing the inner finisher main board
|
End | Contact Epson local service representatives. |