IN PNC Punch Motor 3

Error code
  • 035502 IN PNC Punch Motor 3
Occurrence condition
  • When the home position is initialized, it does not turn off from the home position ON position within 0.05 seconds.
Assumed cause
  • Trouble with FW
  • Deformation, dropout, or failure of the inner punch unit
  • Dirty, missing or broken IN PNC cam drive parts
  • Dirty, missing or broken IN PNC Punch Motor
  • Inner punch unit main board failure
  • Inner Finisher main board failure
Related parts
  • Inner Punch Unit
  • IN PNC cam drive parts
  • IN PNC Punch Motor
  • Inner Punch Unit Main Board
  • Inner Finisher Main Board
Troubleshooting

Step

Confirmation and action

YES

NO

1

Perform FW update.

  • Did the FW update fix the problem?
End

Go to step 2


2

Checking the inner punch unit

  • Is the inner punch unit installed properly?
Go to step 3

Reinstall Inner Punch Unit

3

Checking the IN PNC cam drive parts

  • Are the IN PNC cam drive parts installed properly?
  • Are there any problems with the drive parts?
Go to step 4

Reinstall the IN PNC cam drive parts

Replace if not repaired

4

Check connection

[Part(s) to be checked]

  • IN PNC Punch Motor - Inner Punch Unit Board
  • Inner punch unit board - Inner finisher main board

[Confirmation details]

  • Are there any missing parts or improper installation?
  • Are there any abnormalities (damage/wear) in the relevant locations?
  • Are the connectors connected properly?
  • Are there any problems with the wires?
Go to step 5

In case of falling off or improper installation

  • Reassembly of applicable parts

If there is an abnormality (damage/wear)

  • Replace applicable part

Improper connector connection

  • Clean the wire connector and reinsert it.

If the wire is abnormal

  • Replace the wire.
5

Check the IN PNC Punch Motor operation

Are the following motors operating normally in Failure Verification menu?

  • IN PNC Punch Motor
Go to step 6 Replace the IN PNC Punch Motor
6

Replace the Inner Punch Unit Main Board

  • Replaced the inner punch unit main board and did the problem improve?
End Go to step 7
7

Replacing the inner finisher main board

  • Replaced the inner finisher main board and did the problem improve?
End Contact Epson local service representatives.