FIN Wait Drum Jam (Feed delay)
Error code
- 111 FIN Wait Drum Jam (Feed delay)
Occurrence condition
- The FIN Wait Drum sensor does not turn ON even after the specified time has passed since the FIN Paper Transport Sensor turned ON.
Assumed cause
- Rollers, guides, etc. are dirty, deformed, or not installed properly
- FIN Wait Drum Sensor dirty, missing or defective
- FIN Wait Drum Switching Solenoid dirty, missing or defective
- FIN Wait Drum Motor dirty, missing or defective
- Floor Finisher main board failure
Related parts
- FIN Wait Drum Sensor
- FIN Wait Drum Switching Solenoid
- FIN Wait Drum Motor
- Floor Finisher main board failure
Troubleshooting
Step |
Confirmation and action |
YES |
NO |
|---|---|---|---|
| 1 | Check paper transport path Is there any foreign matter, paper chips, etc. in the paper transport path? |
Remove any foreign objects or pieces of paper |
Go to step 2 |
| 2 | FIN Wait Drum Sensor connector connection check Are the FIN Wait Drum Sensor connected properly? |
Go to step 3 | reconnect FIN Wait Drum Sensor |
| 3 | Operation check of FIN Wait Drum Sensor Is the FIN Wait Drum Sensor operating normally in the diagnostics menu? |
Go to step 4 | replace FIN Wait Drum Sensor |
| 4 | FIN Wait Drum Switching Solenoid connector connection check Are the FIN Wait Drum Switching Solenoid connected properly? |
Go to step 5 | FIN Wait Drum Switching Solenoid |
| 5 | Operation check of FIN Wait Drum Switching Solenoid Is the FIN Wait Drum Switching Solenoid operating normally in the diagnostics menu? |
Go to step 6 | Replace FIN Wait Drum Switching Solenoid |
| 6 | FIN Wait Drum Motor connector connection check Are the FIN Wait Drum Motor connected properly? |
Go to step 7 | Reconnect FIN Paper Transport Motor |
| 7 | Operation check of FIN Wait Drum Motor Is the FIN Wait Drum Motor operating normally in the diagnostics menu? |
Go to step 8 | Replace FIN Wait Drum Motor |
| 8 | Replacing floor finisher main board Have you reconnected and repaired the connector on the floor finisher main board? |
End | Replace floor finisher main board |