Transistor temperature error
Error code: 031003
Occurrence condition
- Board temperature sensor detects abnormal heat generation
Assumed cause
- Board Cooling Fan failure
- Filter clogged at air inlet
- Abnormal heat generation due to drive circuit failure
- Incorrect insertion of FFC in Main Board / Drive Board (open / short)
Defect-related parts
- Board Cooling Fan
- Filters
- Head Drive Board
- Main Board
Troubleshooting
| Step | Confirmation and action | YES | NO |
|---|---|---|---|
| 1 | Check when an error occurs
|
Go to step 2 | Go to step 5 |
| 2 | Check the operation of the Head Drive Board Cooling Fan using individual operation check.
Operates properly? |
Go to step 3 | Go to step 4 |
| 3 | Check the filters at the air inlet
Does the error go away? |
End | Go to step 5 |
| 4 | Replace the Board Cooling Fan
|
End | Go to step 5 |
| 5 | Checking the connection of the FFC connecting the Main Board to the Head Drive Board
Does the error go away? |
End | Go to step 6 |
| 6 | Replace the Head Drive Board
|
End | Go to step 7 |
| 7 | Replace the Main Board
|
End | Contact Epson local service representatives. |