Calibration error
Error code
- 190000 Calibration error
Occurrence condition
- The value written from the SCN main board/ADF main board to the SCN CIS module/ADF CIS module does not match the value read.
Assumed cause
- Disconnection/poor connection of the two FFCs (31-pin/16-pin) connecting the SCN main board/ADF main board and the SCN CIS module/ADF CIS module
SCN CIS module/ADF CIS module failure
- SCN main board/ADF main board failure
Related parts
SCN CISM FFC (signal) *31 pin
SCN CISM FFC (power supply) *16pin
ADF CISM FFC (signal) *31 pin
ADF CISM FFC (power supply) *16pin
SCN Main Board
ADF Main Board
SCN Unit
ADF Unit
Troubleshooting
Step |
Confirmation and action |
Yes |
No |
|---|---|---|---|
| 1 | Check FFC connection
Does the error occur? |
Go to step 2 | End |
| 2 | Replace the CIS Module and board Does the error occur? |
Replace the following parts.
|
End |