Cover open - Main Unit Delivery Cover
Detection condition
- Main Unit Delivery Cover is open.
- With all cover sensors in the Bridge Unit, Finisher Unit, and Saddle Unit detecting that the cover is closed, there are areas where the interlock SW is not closed.
Defect-related parts
- Interlock Main Unit Delivery Cover
- Bridge Unit Joint Stacker (Main Unit Delivery Cover)
- Harness
- Main Board (Bridge Unit)
- Each Inter-Lock Switch of the Bridge Unit, Finisher Unit and Saddle Unit.
- Each cover of the Bridge Unit, Finisher Unit and Saddle Unit.
Troubleshooting
| Step | Confirmation and action | YES | NO |
|---|---|---|---|
| 1 | Check the status of the Main Unit Delivery Cover
|
Go to step 2 | Close the cover correctly |
| 2 | Check the shape of the Main Unit Delivery Cover
|
Replace the Bridge Unit Joint Stacker | Go to step 3 |
| 3 | Check the shape of the Interlock Main Unit Delivery Cover
|
Replace the Interlock switch | Go to step 4 |
| 4 | Check the operation of the Interlock Main Unit Delivery Cover
|
Go to step 6 |
Go to step 5 |
| 5 | Check the installation of the Interlock Main Unit Delivery Cover and connector
|
Fully insert the connectors. | Replace the Interlock switch |
| 6 | Check the operation of each interlock switches With the each cover open, set the cover sensor to the detected state and check the operation of the corresponding interlock SW.
|
Go to step 7 | Go to step 8 |
| 7 | Check the installation of interlock switch xxx and connector
|
Fully insert the connectors. | Replace the corresponding Inter-Lock Switch |
| 8 | Check the shape of the each cover Check the cover shape of pressing each cover sensor and corresponding interlock SW.
|