IN FIN After Width Alignment Motor error 1

Error code
  • 035406 IN FIN After Width Alignment Motor error 1
Occurrence condition
  • Even if the IN FIN After Width Alignment Motor is driven in the HP detection direction for 3 seconds, the IN FIN Post-Alignment Plate HP Sensor does not turn ON.
Assumed cause
  • Deformation, dropout, or failure of IN FIN Post-Alignment Plate
  • Deformation, dropout, or failure of IN FIN Post-Alignment Plate Drive Parts
  • IN FIN After Width Alignment Motor dirty, missing or defective
  • IN FIN Post-Alignment Plate HP Sensor dirty, missing or defective
  • Inner Finisher main board failure
Related parts
  • IN FIN Post-Alignment Plate
  • IN FIN Post-Alignment Plate Drive Parts
  • IN FIN After Width Alignment Motor
  • IN FIN Post-Alignment Plate HP Sensor
  • Inner Finisher Main Board
Troubleshooting
Step Confirmation and action YES NO
1

Check the IN FIN Post-Alignment Plate

  • Is the IN FIN Post-Alignment Plate assembled correctly?
Go to step 2 If the IN FIN Post-Alignment Plate cannot be moved manually, fix the part where it is stuck.
2

Check the IN FIN Post-Alignment Plate Drive Parts

  • Is the IN FIN Post-Alignment Plate Drive Parts installed properly?
  • Are there any problems with the drive parts?
Go to step 3

Reinstall the IN FIN Post-Alignment Plate Drive Parts

Replace if not repaired

3

Check the IN FIN After Width Alignment Motor

[Part(s) to be checked]

  • IN FIN After Width Alignment Motor - Inner Finisher Main Board

[Confirmation details]

  • Is the IN FIN After Width Alignment Motor missing or improperly installed?
  • Is there any abnormality (damage/wear) in the IN FIN After Width Alignment Motor?
  • Are the connectors connected properly?
  • Are there any problems with the wires?
Go to step 4

In case of falling off or improper installation

  • Reassembly of the IN FIN After Width Alignment Motor

If there is an abnormality (damage/wear)

  • Replace the IN FIN After Width Alignment Motor

Improper connector connection

  • Clean the wire connector and reinsert it.

If the wire is abnormal

  • Replace the wire.
4

Check the operation of the IN FIN After Width Alignment Motor

Are the following motors operating normally in Failure Verification menu?

  • Width Adjustment Test (A3)
  • Width Adjustment Test (LD)
Go to step 5 Replace the IN FIN After Width Alignment Motor
5

Check the IN FIN Post-Alignment Plate HP Sensor

[Part(s) to be checked]

  • IN FIN Post-Alignment Plate HP Sensor - Inner Finisher Main Board

[Confirmation details]

  • Is the IN FIN Post-Alignment Plate HP Sensor missing or improperly installed?
  • Is there any abnormality (damage/wear) in the IN FIN Post-Alignment Plate HP Sensor?
  • Are the connectors connected properly?
  • Are there any problems with the wires?
Go to step 6

In case of falling off or improper installation

  • Reassembly of the IN FIN Post-Alignment Plate HP Sensor

If there is an abnormality (damage/wear)

  • Replace the IN FIN Post-Alignment Plate HP Sensor

Improper connector connection

  • Clean the wire connector and reinsert it.

If the wire is abnormal

  • Replace the wire.
6

Check the operation of the IN FIN Post-Alignment Plate HP Sensor

Are the following sensor operating normally in Failure Verification menu?

  • IN FIN Post-Alignment Plate HP Sensor
Go to step 7 Replace the IN FIN Post-Alignment Plate HP Sensor
7

Replacing the inner finisher main board

  • Replaced the inner finisher main board and did the problem improve?
End Contact Epson local service representatives.