Head ID reading NACK error
Error code
- 031120 NVT check ID read NACK error 0
- 031121 NVT check ID read NACK error 1
- 031122 NVT check ID read NACK error 2
- 031123 NVT check ID read NACK error 3
- 031124 NVT check ID read NACK error 4
- 031125 NVT check ID read NACK error 5
- 031160 NVT nozzle rank read NACK error 0
- 031161 NVT nozzle rank read NACK error 1
- 031162 NVT nozzle rank read NACK error 2
- 031163 NVT nozzle rank read NACK error 3
- 031164 NVT nozzle rank read NACK error 4
- 031165 NVT nozzle rank read NACK error 5
- 031220 NVT nozzle rank mode value read NACK error 0
- 031221 NVT nozzle rank mode value read NACK error 1
- 031222 NVT nozzle rank mode value read NACK error 2
- 031223 NVT nozzle rank mode value read NACK error 3
- 031224 NVT nozzle rank mode value read NACK error 4
- 031225 NVT nozzle rank mode value read NACK error 5
- 031280 NVT mode value rank nozzles count read NACK error 0
- 031281 NVT mode value rank nozzles count read NACK error 1
- 031282 NVT mode value rank nozzles count read NACK error 2
- 031283 NVT mode value rank nozzles count read NACK error 3
- 031284 NVT mode value rank nozzles count read NACK error 4
- 031285 NVT mode value rank nozzles count read NACK error 5
- 031380 Head ID reading NACK error
Occurrence condition
- When head replacement, Nack does not return when the main unit accesses the memory to read the memory value.
- Noise occurred when reading memory information or communication failed.
- The contents written to memory are incorrect.
Assumed cause
- Data failure due to noise
- Head FFC failure / connection failure
- Head Unit failure
Defect-related parts
- Head FFC
- Head Unit
- Main Board
Troubleshooting
| Step | Confirmation and action | YES | NO |
|---|---|---|---|
| 1 | Checking the connection of FFC connecting to the Head Unit and Main Board
Does the error go away? |
End | Go to step 2 |
| 2 | Replace the Head Unit
|
End | Go to step 3 |
| 3 | Replace the Main Board
|
End | Contact Epson local service representatives. |