FIN Alignment Front Jam
Error code
- 113 FIN Alignment Front Jam
Floor Finisher
Occurrence condition
- FIN Alignment Plate Front HP Sensor OFF is not detected even after the specified time has passed since the FIN Width Adjustment Front Motor was ON during initial operation.
Assumed cause
- FIN Alignment Plate Front Guide dirty, deformed, or not fitted properly .
- FIN Alignment Plate Front HP Sensor dirty, missing or defective.
- FIN Width Adjustment Front Motor dirty, missing or defective.
- Floor Finisher main board failure
Related parts
- FIN Alignment Plate Front Guide
- FIN Alignment Plate Front HP Sensor
- FIN Width Alignment Front Motor
- Floor Finisher main board failure
Troubleshooting
Step |
Confirmation and action |
YES |
NO |
|---|---|---|---|
| 1 | Checking FIN Alignment Plate Front Guide. Is the FIN Alignment Plate Front Guide installed properly? Or is it dirty, deformed or worn? |
Clean FIN Alignment Plate Front Guide. Replace if not repaired |
Go to step 2 |
| 2 | FIN Alignment Plate Front HP Sensor connector connection check Are the FIN Alignment Plate Front HP Sensor connected properly? |
Go to step 3 | Reconnect FIN Alignment Plate Front HP Sensor |
| 3 | Operation check of FIN Alignment Plate Front HP Sensor Is the FIN Alignment Plate Front HP Sensor operating normally in the diagnostics menu? |
Go to step 4 | Replace FIN Alignment Plate Front HP Sensor |
| 4 | FIN Width Alignment Front MotorCheck the connection of the connector Are the FIN Width Alignment Front Motor connected properly? |
Go to step 5 | Reconnect FIN Width Alignment Front Motor. |
| 5 | FIN Width Alignment Front MotorOperation Check Is the FIN Width Alignment Front Motor operating normally in the diagnostics menu? |
Go to step 6 | Replace FIN Width Alignment Front Motor |
| 6 | Replacing floor finisher main board Have you reconnected and repaired the connector on the floor finisher main board? |
End | Replace floor finisher main board |
Inner Finisher
Occurrence condition
- IN FIN Alignment Plate Rear HP Sensor OFF is not detected even after the specified time has passed since the FIN Width Adjustment Rear motor was ON during initial operation.
Assumed cause
- IN FIN Alignment Plate Front Guide dirty, deformed, or not fitted properly .
- IN FIN Alignment Plate Front HP Sensor dirty, missing or defective
- IN FIN Width Alignment Front Motor dirty, missing or defective
- Inner Finisher main board failure
Related parts
- IN FIN Alignment Plate Front Guide
- IN FIN Pre-Alignment Plate HP Sensor
- IN FIN Width Alignment Front Motor
- Inner Finisher Main Board
Troubleshooting
Step |
Confirmation and action |
YES |
NO |
|---|---|---|---|
| 1 | Checking IN FIN Alignment Plate Front Guide Is the IN FIN Alignment Plate Front Guide installed properly? Or is it dirty, deformed or worn? |
Clean FIN Alignment Plate Front Guide. Replace if not repaired |
Go to step 2 |
| 2 | FIN Alignment Plate Front HP Sensor connector connection check Are the IN FIN Alignment Plate Front HP Sensor connected properly? |
Go to step 3 | Reconnect IN FIN Alignment Plate Front HP Sensor |
| 3 | Operation check of IN FIN Alignment Plate Front HP Sensor Is the IN FIN Alignment Plate Front HP Sensor operating normally in the diagnostics menu? |
Go to step 4 | Replace IN FIN Alignment Plate Front HP Sensor. |
| 4 | IN FIN Width Alignment Front Motor connector connection check Are the IN FIN Width Alignment Front Motor connected properly? |
Go to step 5 | Reconnect the IN FIN Width Alignment Front Motor. |
| 5 | Operation check of IN FIN Width Alignment Front Motor Is the IN FIN Width Alignment Front Motor operating normally in the diagnostics menu? |
Go to step 6 | Replace the IN FIN Width Alignment Front Motor. |
| 6 | Replacing the inner finisher main board Have you reconnected and repaired the connector on the inner finisher main board? |
End | Replace Inner finisher main board |