SDL Stapler Drive Motor error 2
Error code
- 035015 SDL Stapler Drive Motor error 2
Occurrence condition
- 00127 SDL Stapler Jam was detected twice in a row.
(Second jam detection condition: A motor lock was detected while the SDL Stapler Drive Motor was running.)
Assumed cause
- SDL Stapler unit dirty, falling off, or malfunctioning
- SDL Stapler unit drive parts dirty, falling off, or malfunctioning
- SDL Stapler Drive Motor dirty, falling off, or malfunctioning
- SDL Unit Main Board failure
Related parts
- SDL Stapler Unit
- SDL Stapler Unit Drive Parts
- SDL Stapler Drive Motor
- SDL Unit Main Board
Troubleshooting
| Step | Confirmation and action | YES | NO |
|---|---|---|---|
| 1 | Check the SDL Stapler Unit
|
Go to step 2 | If the SDL Stapler Unit does not work manually, fix the part where it is stuck. |
| 2 | Check the SDL Stapler Unit Drive Parts
|
Go to step 3 | Reinstall the SDL Stapler Unit Drive Parts Replace if not repaired |
| 3 | Check the SDL Stapler Unit [Part(s) to be checked]
[Confirmation details]
|
Go to step 4 | In case of falling off or improper installation
If there is an abnormality (damage/wear)
Improper connector connection
If the wire is abnormal
|
| 4 | Check the operation of the SDL Stapler Drive Motor Are the following motors operating normally in Failure Verification menu?
|
Go to step 5 | Replace the SDL Stapler Unit. |
| 7 | Replace SDL Unit Main Board
|
End | Contact Epson local service representatives. |