Paper Stuck Jam: High Capacity Unit

Occurrence condition
  • The sensor detected paper presence when the power was turned on, when power saving was restored, and when the cover was opened and closed.
Defect-related parts
  • PF paper detection sensor
  • Controller Board
  • Mechanical Controller Board
Troubleshooting
Step Confirmation and action YES NO
1

Check the paper feed path

  • At this time, check that the paper is not caught between the High Capacity Unit and the Main Unit.
Remove any foreign objects or pieces of paper Go to step 2
2

Check for installation and dirt of sensor

  • Are the roller sensors listed on the defect-related parts clean and properly installed?
Go to step 3

Clean or reinstall the sensor


3

Attach sensor and check connector connection

  • Is there any abnormality in the sensor or half-inserted in the connector?
Connect securely

Replace sequentially

  • Sensors
4

Board replacement and confirmation of phenomenon reproduction

  • Replace the Controller Board and check the reproduction of the phenomenon for the content of the defect report.
    Is the phenomenon continuing?  

Replace the parts one by one.

  • Mechanical Controller Board
End