BRG Front Cover Open

Detection condition
  • The BRG Front Cover is open.
Defect-related parts
  • BRG Front Cover Sensor
  • BRG Front Cover
  • Harness
  • Bridge unit board
Troubleshooting
Step Confirmation and action YES NO
1

Check the status of BRG Front Cover

  • Is the BRG Front Cover closed correctly?
Go to step 2 Close the cover correctly
2

Check the status of BRG Front Cover
Check the shape of the part that presses the BRG Front Cover Sensor.

  • Is there any deformation or damage on the corresponding part?
Replace the BRG Front Cover Go to step 3
3

Check the shape of BRG Front Cover Sensor

  • Is the BRG Front Cover Sensor damaged?
Replace the sensor. Go to step 4
4

Check the operation of the BRG Front Cover Sensor
Check the operation of the BRG Front Cover Sensor using the diagnostic function.

  • Judgment: Does the signal change by opening/closing the cover?

Replace the mechanical control board

Go to step 5
5

Installation of the BRG Front Cover Sensor and connector connection confirmation

  • Is there any abnormality in the BRG Front Cover Sensor or half-inserted in the connector?
Fully insert the connectors.

Replace the sensor.