LFT* PID overload error / LFT* PID lock error
Error code
- 000161 LFT1 PID overload error
- 000181 LFT2 PID overload error
- 000201 LFT3 PID overload error
- 000221 LFT4 PID overload error
- 000164 LFT1 PID lock error
- 000184 LFT2 PID lock error
- 000204 LFT3 PID lock error
- 000224 LFT4 PID lock error
Occurrence condition
- C1 Motor cannot operate due to large motor load
- C2 Motor cannot operate due to large motor load
- C3 Motor cannot operate due to large motor load
- C4 Motor cannot operate due to large motor load
- C1 Motor cannot rotate
- C2 Motor cannot rotate
- C3 Motor cannot rotate
- C4 Motor cannot rotate
Assumed cause
- Incorrect setting of paper, setting of number of sheets exceeding specifications
- Foreign materials in the cassette
- Gear trains for lifting cassette are damaged or have foreign objects.
- The load when the hopper moves up is unexpectedly high
- The load on the cassette lift-up motor exceeds the expectation and the motor does not rotate at all
Related parts
- Cassette Unit (C1-C4)
- Lift Up Motor Sensor, C1-C4
- Lift up Motor, C1-C4
- Mechanical control board
- Main Board
Troubleshooting
| Step | Confirmation and action | YES | NO |
|---|---|---|---|
| 1 | Check paper cassette (1) |
Go to step 2 | Reduce the number of sheets of paper or remove foreign objects. |
| 2 | Check cassette (2) |
Go to step 3 | Replace the Cassette Unit |
| 3 | Check the gear trains |
Replace the mechanical control board and then the Main Board. |
Remove the foreign objects or replace the Lift Up Motor, C1-C4. |