Paper Output Tray Rib HP Sensor Error
Paper Ejection Tray Rib Sensor Error : 034200
Cause
- Paper Ejection Tray Rib Upper Limit Sensor or Paper Ejection Tray Rib Lower Limit Sensor are not detected.
Assumed cause
- Paper Ejection Tray Rib Upper Limit Sensor does not turn ON
- Paper Ejection Tray Rib Lower Limit Sensor does not turn ON
- Mechanical Controller board
Troubleshooting
| Step | Confirmation and action | YES | NO |
|---|---|---|---|
| 1 | Check the connector connection of the Paper Ejection Tray Rib Upper Limit Sensor and Paper Ejection Tray Rib Lower Limit Sensor
|
Connect securely |
Go to step 2 |
| 2 | Replace the Paper Ejection Tray Rib Upper Limit Sensor and implement mechanical initialization
|
- |
Replace the Controller Board |