Cover open, Bridge unit top cover
Detection condition
- The Top Cover is open.
Defect-related parts
- BRG Top Cover Sensor
- Top Cover
- Harness
- Bridge unit board
Troubleshooting
| Step | Confirmation and action | YES | NO |
|---|---|---|---|
| 1 | Check the status of the BRG Top Cover
|
Go to step 2 | Close the cover correctly |
| 2 | Check the shape of Top Cover
|
Replace the Top Cover | Go to step 3 |
| 3 | Check the shape of BRG Top Cover Sensor
|
Replace the sensor. | Go to step 4 |
| 4 | Check the operation of the BRG Top Cover Sensor Check the operation using the diagnostic function.
|
Replace the Main Board (Bridge Unit) |
Go to step 5 |
| 5 | Installation of the BRG Top Cover Sensor and connector connection confirmation
|
Fully insert the connectors. | Replace the sensor. |