306030204 FIN Shift Arm Release Position HP Sensor

Program No. Menu Name Judgment method Remarks
306030204 FIN Shift Arm Release Position HP Sensor Check the sensor by running [306030106 FIN Shift Arm Initial Operation] and [306030105 FIN Shift Arm Width Alignment Test (A3)]. TRUE: Detection
FALSE: No Detection
Default: FALSE
  1. Execute [306030106 FIN Shift Arm Initial Operation] in the Service Support mode.
  2. After executing step 1, check that the [306030204 FIN Shift Arm Release Position HP Sensor] status changes to “TRUE”.


    * The sensor status changes to “FALSE” when [306030105 FIN Shift Arm Width Alignment Test (A3)] is executed.