FIN Width Adjustment Motor Rear Error
Error code
- 035012 FIN Width Adjustment Motor Rear Error
Occurrence condition
- 00114 FIN Post-Alignment jam was detected twice in a row.
Assumed cause
- Deformation, dropout, or failure of FIN Alignment Plate Rear
- Deformation, dropout, or failure of IFIN Alignment Plate Rear
- FIN Alignment Plate Rear Motor dirty, missing or defective
- FIN Post-Alignment Plate HP Sensor dirty, missing or defective
- Floor Finisher main board failure
Related parts
- FIN Alignment Plate Rear
- FIN Alignment Plate Rear Drive Parts
- FIN After Width Alignment Motor
- FIN Alignment Plate Rear HP Sensor
- Floor Finisher Main Board
Troubleshooting
| Step | Confirmation and action | YES | NO |
|---|---|---|---|
| 1 | Check the FIN Alignment Plate Rear
|
Go to step 2 | If the FIN Alignment Plate Rear cannot be moved manually, fix the part where it is stuck. |
| 2 | Check the FIN Alignment Plate Rear Drive Parts
|
Go to step 3 | Reinstall the FIN Alignment Plate Rear Drive Parts Replace if not repaired |
| 3 | Check the FIN Width Adjustment Motor Rear [Part(s) to be checked]
[Confirmation details]
|
Go to step 4 | In case of falling off or improper installation
If there is an abnormality (damage/wear)
Improper connector connection
If the wire is abnormal
|
| 4 | Operation check of FIN After Width Alignment Motor. Are the following motors operating normally in Failure Verification menu?
|
Go to step 5 | Replace FIN Width Adjustment Rear Motor. |
| 5 | Check the FIN Alignment Plate Rear HP Sensor [Part(s) to be checked]
[Confirmation details]
|
Go to step 6 | In case of falling off or improper installation
If there is an abnormality (damage/wear)
Improper connector connection
If the wire is abnormal
|
| 6 | Operation check of FIN Alignment Plate Rear HP Sensor Are the following sensor operating normally in Failure Verification menu?
|
Go to step 7 | Replace the corresponding sensor |
| 7 | Replacing floor finisher main board
|
End | Contact Epson local service representatives. |