FIN Pulling Guide Motor Jam
Error code
- 132 FIN Pulling Guide Motor Jam
Floor Finisher
Occurrence condition
- The FIN Paper Pulling Paddle HP Sensor does not detect any changes even after the FIN Pulling Guide Motor moves in the direction of the HP sensor change for a certain period of time.
Assumed cause
- FIN Pulling Guide dirty, deformed, or not fitted properly
- FIN Pulling Paddle Release HP Sensor dirty, missing or defective
- FIN Pulling Guide Motor dirty, missing or defective
- Floor Finisher main board failure
Related parts
- FIN Pulling Guide
- FIN Paper Pulling Paddle HP Sensor
- FIN Pulling Guide Motor
- Floor Finisher main board failure
Troubleshooting
Step |
Confirmation and action |
YES |
NO |
|---|---|---|---|
| 1 | Checking FIN Pulling Guide Is the FIN Pulling Guide installed properly? Or is it dirty, deformed or worn? |
Clean the FIN Pulling Guide Replace if not repaired |
Go to step 2 |
| 2 | FIN Paper Pulling Paddle HP SensorCheck the connection of the connector Are the FIN Paper Pulling Paddle HP Sensor connected properly? |
Go to step 3 | reconnect FIN Paper Pulling Paddle HP Sensor |
| 3 | FIN Paper Pulling Paddle HP SensorOperation Check Is the FIN Paper Pulling Paddle HP Sensor operating normally in the diagnostics menu? |
Go to step 4 | Replace FIN Paper Pulling Paddle HP Sensor |
| 4 | FIN Pulling Guide MotorCheck the connection of the connector Are the FIN Pulling Guide Motor connected properly? |
Go to step 5 | reconnect FIN Pulling Guide Motor |
| 5 | FIN Pulling Guide MotorOperation Check Is the FIN Pulling Guide Motor operating normally in the diagnostics menu? |
Go to step 6 | Replace FIN Pulling Guide Motor |
| 6 | Replacing floor finisher main board Have you reconnected and repaired the connector on the floor finisher main board? |
End | Replace floor finisher main board |
Inner Finisher
Occurrence condition
- Even if the IN FIN Pulling Paddle Motor is moved in the direction of HP sensor fluctuation for a certain period of time, the change of IN FIN Paper Pulling Paddle HP Sensor is not detected.
Assumed cause
- IN FIN Pulling Paddle dirty, deformed, or not fitted properly
- IN FIN Paper Pulling Paddle HP Sensor dirty, missing or defective
- IN FIN Pulling Paddle Motor dirty, missing or defective
- Inner Finisher main board failure
Related parts
- IN FIN Pulling Paddle
- FIN Paper Pulling Paddle HP Sensor
- IN FIN Pulling Paddle Motor
- Inner Finisher Main Board
Troubleshooting
Step |
Confirmation and action |
YES |
NO |
|---|---|---|---|
| 1 | Checking IN FIN Pulling Paddle Is the IN FIN Pulling Paddle installed properly? Or is it dirty, deformed or worn? |
Clean IN FIN Pulling Paddle Replace if not repaired |
Go to step 2 |
| 2 | IN FIN Paper Pulling Paddle HP SensorCheck the connection of the connector Are the IN FIN Pulling Paddle Release HP Sensor IN FIN Paper Pulling Paddle HP Sensor connected properly? |
Go to step 3 | reconnect IN FIN Paper Pulling Paddle HP Sensor |
| 3 | IN FIN Paper Pulling Paddle HP SensorOperation Check Is the IN FIN Paper Pulling Paddle HP Sensor operating normally in the diagnostics menu? |
Go to step 4 | Replace IN FIN Paper Pulling Paddle HP Sensor |
| 4 | IN FIN Pulling Paddle MotorCheck the connection of the connector Are the IN FIN Pulling Paddle Motor connected properly? |
Go to step 5 | reconnect IN FIN Pulling Paddle Motor |
| 5 | IN FIN Pulling Paddle MotorOperation Check Is the IN FIN Pulling Paddle Motor operating normally in the diagnostics menu? |
Go to step 6 | Replace IN FIN Pulling Paddle Motor |
| 6 | Replacing the inner finisher main board Have you reconnected and repaired the connector on the inner finisher main board? |
End | Replace Inner finisher main board |