SDL Stapler Jam

Error code
  • 127 SDL Stapler Jam
Occurrence condition
  • After starting SDL Stapler Drive Motor, HP of SDL Stapler cannot be detected.
  • A motor lock was detected while the SDL Stapler Drive Motor was running.
Assumed cause
  • Staple Jam
  • SDL Stapler unit dirty, falling off, or malfunctioning
  • Failure of the SDL main board
  • Floor Finisher main board failure
Related parts
  • SDL Stapler Cartridge
  • SDL Stapler Unit
  • SDL main board
  • Floor Finisher Main Board
Troubleshooting

Step

Confirmation and action

YES

NO

1

Staple confirmation

Are staples jammed?

remove jammed staples from staple cartridge

Go to step 2

2

SDL Stapler Drive MotorChecking

Can the SDL stapler drive motor rotate smoothly manually?

Go to step 3 Replace the SDL Stapler Unit.
3

SDL Stapler UnitCheck the connection of the connector

Are the SDL Stapler Units properly connected?

Go to step 4 Reconnect the SDL Stapler Unit.
4

SDL Stapler UnitOperation Check

Is the SDL Stapler Drive Motor operating normally in the diagnostics menu?

Go to step 5 Replace the SDL Stapler Unit.
5

Replacing the SDL main board

Have you reconnected and repaired the connector on the SDL main board?

Go to step 6 Replace the SDL Main Board.
6

Replacing floor finisher main board

Have you reconnected and repaired the connector on the floor finisher main board?

End Replace floor finisher main board