Home position detection failure
Error code
- 100016 Home position detection failure
Occurrence condition
- LED of Flat Bed CISM is not lighted
- Flat Bed CISM cannot read
- Flat Bed home position pattern not found in range
Assumed cause
SCN CIS Module failure
- SCN CIS Module harness failure
- SCN Upper Case failure (Contamination on the home position pattern)
- SCN drive motor (SCN CR) failure / Harness failure
SCN Board connection harness failure
SCN Board failure
- Incorrect installation of the scanner in the printer
Related parts
- SCN CIS Module
- SCN Upper Case
- ADF/SCN Unit
- SCN Board
- SCN Board connection harness
- Incorrect installation of the scanner in the printer
Troubleshooting
Step |
Confirmation and action |
Yes |
No |
|---|---|---|---|
1 |
LED lighting check of the SCN CIS module
|
Go to step 3 |
Go to step 2 |
| 2 | Check for disconnection or partial insertion of the SCN CIS module FFC connector.
|
If reconnecting the connector resolves the issue: End. If reconnecting does not resolve the issue: Proceed to Step 3. |
Go to step 3 |
| 3 | SCN CIS Module / SCN CR Installation Check
|
Go to step 4 |
End |
| 4 | SCN Upper Case – Condition Check
|
Go to step 5 | End |
| 5 | Replace the SCN CIS Module
|
Go to step 6 | End |
| 6 | Replace the SCN Board
|
Go to step 7 | End |
| 7 | Replace the ADF/SCN Unit
|
Contact EPSON Local Service Representatives | End |