60209 ADF/SCN Individual Settings Reset
Resets all offset values in the following menus.
- 60205 ADF Manual Skew
- 60206 FB Scan Position Offset
- 60207 ADF Scan Position Offset
- 60208 ADF Scaling Offset
- Start the service support mode.

- Select [06 Individual Adjustment].

- Select the [ADF/SCN] tab.
- Select [60209 ADF/SCN Individual Settings Reset].
- Press [Execution].