Transistor temperature error

Error code: 031003

Occurrence condition
  • Board temperature sensor detects abnormal heat generation
Assumed cause
  • Board Cooling Fan failure
  • Filter clogged at air inlet
  • Abnormal heat generation due to drive circuit failure
  • Incorrect insertion of FFC in Main Board / Drive Board (open / short)
Defect-related parts
  • Board Cooling Fan
  • Filters
  • Head Drive Board
  • Main Board
Troubleshooting
Step Confirmation and action YES NO
1

Check when an error occurs

  • Does it occur immediately after printing starts?
Go to step 2 Go to step 5
2

Check the operation of the Head Drive Board Cooling Fan using individual operation check.

  • Check individual operation from service support mode (22: input, 222130: board Cooling Fan)

Operates properly?

Go to step 3 Go to step 4
3

Check the filters at the air inlet

  • Check if the filter at air inlet is clogged with dust
  • Check if there are any factors obstructing intake air

Does the error go away?

End Go to step 5
4

Replace the Board Cooling Fan

  • Does the error go away?
End Go to step 5
5

Checking the connection of the FFC connecting the Main Board to the Head Drive Board

  • Check if there is no problem inserting FFC
  • Check the route visually for FFC disconnection and check for scratches

Does the error go away?

End Go to step 6
6

Replace the Head Drive Board

  • Does the error go away?
End Go to step 7
7

Replace the Main Board

  • Does the error go away?
End

Contact EPSON Local Service Representatives