Guide PF Inner Lever Assy

  1. Open the right door unit (A).


    Assembly / 組み立て

    When closing the right door unit, it may not close due to interference with the tumbler (A) that was tilted toward the front when other parts were repaired.

    If the right door unit does not close, check the position of the tumbler, and if it is protruding toward the front, fit the tip of the tumbler plate (C) into the hole (B) in the main unit.

  2. Raise the Guide PF Inner (A) and push it in the direction of the arrow to release the dowel, then remove the Guide PF Inner.


    Assembly / 組み立て

    Put the shaft (A) on the inward side of the lever (B) and attach it.

  3. Pull out the tab of the Tumbler (A) from the hole, then raise the Tumbler.
  4. Remove the 2 screws that secure the Guide PF Inner Lever Assy (A).

    • : 3x8M
  5. Remove the dowel, and remove the Guide PF Inner Lever Assy (A).


    Assembly / 組み立て

    Be careful not to let the C1 Pickup Unit cable (A) get caught between components.

    Before installing the Guide PF Inner Lever Assy (B), be sure to put protruding cables into the C1 Pickup Unit.