PCIMGR access right gain/return error
Error code
- 032519 PCIMGR access right gain failure error
- 032520 PCIMGR access right return error
Occurrence condition
Poor connection between the main board and the head control board (cable disconnected/inserted loosely/slanted, etc.)
Damage to the Main board
Damage to the Head control board
Defect-related parts
- Head Unit
- Main Board
Troubleshooting
| Step | Confirmation and action | YES | NO |
|---|---|---|---|
| 1 | Check the connection of the connector Did the error disappear after reconnecting the connector? |
End | Go to step 2 |
| 2 | Replace the Head Unit Does the error go away? |
End | Go to step 3 |
| 3 | Replacement of Main Board Does the error go away? |
Contact EPSON Local Service Representatives | End |