ADF/SCN Unit - After replacement
- Turn the power ON.

- Press [Execution].

- Set the A4-DS chart on ADF tray and press [Execute].

ADF Scan Position/ Scaling Calibration (600dpi) is performed.
- Set the A4-DS chart on ADF tray again, and press [Execute].

ADF Scan Position/ Scaling Calibration (300dpi Continuous feed) is performed.
- Set the A4-DS chart on ADF tray again, and press [Execute].

ADF Scan Position/ Scaling Calibration (300dpi Single feed) is performed.
- Press [Execution].

- Press [OK] to complete the menu.