Head Control Board Cooling Fan
Error code
- 030921 Head Drive Board Cooling Fan error
Occurrence condition
- Fan has not reached the specified rotation speed.
Assumed cause
- foreign substances tucking
- Poor connection of connector
- Fan Motor failure
- Main Board failure
Defect-related parts
- Head Board Cooling Fan
- Main Board
Troubleshooting
| Step | Confirmation and action | YES | NO |
|---|---|---|---|
| 1 | Check the fan driving operation
<Diagnostic function>
Did you confirm the operating sound of the fan? |
Go to step 2 | Go to step 3 |
| 2 | Check fan lock signal
<Diagnostic function>
Did you confirm the value changing? |
Replace the Main Board |
Go to step 4 |
| 3 | foreign substances tucking
|
Removal of foreign substances | Go to step 4 |
| 4 | Check the connection of the connector
|
Connect securely |
Replace a fan |