CRCM access error

Error code
  • 033006
  • 033007
  • 033008
Occurrence condition
  • 033006 Data reading error from CRCM
  • 033007 Data writing error to CRCM
  • 033008 No data found during CRCM access
Assumed cause
  • Poor connection of the cable and circuit between the SOC and CRCM, and CSIC on the main board

Defect-related parts
  • Main Board
  • I/C Sensor Unit
  • Cable between main board and I/C sensor
Troubleshooting
Step Confirmation and action YES NO
1

Check the connection of FFC and cables connecting to I/C Sensor and Main Board

  • Check if there is no problem with insertion.
  • Visually check the route and check for any damage.
  • Does the error go away?
Go to step 2 End
2

Replace the I/C Sensor

  • Does the error go away?

Replacement of Main Board

End