CRCM access error
Error code
- 033006
- 033007
- 033008
Occurrence condition
- 033006 Data reading error from CRCM
- 033007 Data writing error to CRCM
- 033008 No data found during CRCM access
Assumed cause
Poor connection of the cable and circuit between the SOC and CRCM, and CSIC on the main board
Defect-related parts
- Main Board
- I/C Sensor Unit
- Cable between main board and I/C sensor
Troubleshooting
| Step | Confirmation and action | YES | NO |
|---|---|---|---|
| 1 | Check the connection of FFC and cables connecting to I/C Sensor and Main Board
|
Go to step 2 | End |
| 2 | Replace the I/C Sensor
|
Replacement of Main Board |
End |