LFT* PID overload error / LFT* PID lock error
Error code
- 000161 LFT1 PID overload error
- 000181 LFT2 PID overload error
- 000201 LFT3 PID overload error
- 000221 LFT4 PID overload error
- 000164 LFT1 PID lock error
- 000184 LFT2 PID lock error
- 000204 LFT3 PID lock error
- 000224 LFT4 PID lock error
Occurrence condition
- C1 Motor cannot operate due to large motor load
- C2 Motor cannot operate due to large motor load
- C3 Motor cannot operate due to large motor load
- C4 Motor cannot operate due to large motor load
- C1 Motor cannot rotate
- C2 Motor cannot rotate
- C3 Motor cannot rotate
- C4 Motor cannot rotate
Assumed cause
- Incorrect setting of paper, setting of number of sheets exceeding specifications
- Foreign materials in the cassette
- Damage or foreign substances to Lift rotating component part
- Unexpectedly high load due to hopper up drive
- The load on the cassette lift-up motor exceeds the expectation and the motor does not rotate at all
Related parts
- Cassette Unit (C1-C4)
- Lift Up Motor Sensor, C1-C4
- Lift up Motor, C1-C4
- MCU Board
- Main Board
Troubleshooting
| Step | Confirmation and action | YES | NO |
|---|---|---|---|
| 1 | Check cassette (1) |
Go to step 2 | Reduce the number of paper sets or remove foreign objects. |
| 2 | Check cassette (2) |
Go to step 3 | Replace the Cassette Unit |
| 3 | Confirmation of rotating component part |
Replace the MCU Board and the Main Board, in that order. |
Foreign matter removal or Lift Up Motor, C1-C4 replacement |