Additional Main Board over-voltage error
Error code
- 060011 Additional Main Board over-voltage error
Occurrence condition
- Over-voltage detected on the C2 Additional Main Board or C3C4 Additional Main Board.
Assumed cause
C3C4 Additional Main Board failure
Connection harness (1) (C3C4 Drawer Connector) failure
Connection harness (2) (C2 Drawer Connector) failure
C2 Additional Main Board failure
- Connection harness (3) (C1 Drawer Connector) failure
- Connection harness (4) (Main Unit Drawer Connector) failure
- MCU board failure
- Failure of the Main board
Defect-related parts
- C3C4 Additional Main Board
- Connection harness (1) (C3C4 Drawer Connector)
- Connection harness (2) (C2 Drawer Connector)
- C2 Additional Main Board
- Connection harness (3) (C1 Drawer Connector)
- Connection harness (4) (Main Unit Drawer Connector)
- MCU Board
- Main Board
Troubleshooting
| Step | Confirmation and action | YES | NO |
|---|---|---|---|
| 1 | Power is turned on while only the Additional 1st Cassette is connected
Does the error occur when turning the power on again? |
Go to step 2 | End |
| 2 | Replace the C2 Additional Main Board
|
Go to step 3 | End |
| 3 | Replace the connection harness (3) (C1 Drawer Connector)
|
Go to step 4 | End |
| 4 | Replace the connection harness (4) (Main Unit Drawer Connector)
|
Go to step 5 | End |
| 5 | Replace the C3C4 Additional Main Board
|
Go to step 6 | End |
| 6 | Replace the connection harness (1) (C3C4 Drawer Connector)
|
Go to step 7 | End |
| 7 | Replace the connection harness (2) (C2 Drawer Connector)
|
Go to step 8 | End |
| 8 | Replace the MCU board
|
Go to step 9 | End |
| 9 | Replacement of Main Board
|
Contact EPSON Local Service Representatives | End |