Ruled line misalignment or Character distortion
Assumed cause
- Paper transport failure
- Head correction value offset
- Head nozzle clogging
- Foreign objects on Nozzle surface
- Waveform data is not transferred to the Head.
- Image data generation or transfer failure
Defect-related parts
- Head Drive Board
Due to failure in applying voltage, ink droplets fired positions differ between head chips. - Belt Drawer Unit
Failure in the feeding operation or ink droplets are fired onto incorrect positions - Head Unit
Error of alignment correction values - HP Sensor, PG
PG is wider than the set value - Main Board
Abnormal input signal to head - Head FFC
Image data transfer failure - Anti Static Brush unit
Poor paper adsorbing power due to defective paper static - High Voltage Board
Abnormal input voltage
Troubleshooting
| Step | Confirmation and action | YES | NO |
|---|---|---|---|
| 1 | Run Head Cleaning (CL3)
|
End of work | Go to step 2 |
| 2 | Print the 20102 Ruled Line Pattern on non-user paper
(Due to user paper or separation. Use unopened or conditioned paper) |
End of work | Go to step 3 |
| 3 | Print the “Adsorption Check Pattern"
(Paper conveyance failure or separation of ink droplet landing position deviation) |
Go to step 5 | Go to step 4 |
| 4 | Replace the Head Drive Board
|
End of work | Go to step 5 |
| 5 | Clean the Belt Drawer Unit
(Identifying poor suction due to poor charging) |
End of work | Go to step 6 |
| 6 | Replace the Belt Drawer Unit
(Identifying defective charging due to belt flaws and charging roller contamination) |
End of work | Go to step 7 |
| 7 | Replace the Head Unit
|
End of work | Replace the parts/components to be checked one by one. |