SEL1 PID reverse error / SEL1 PID lock error / SEL1 PID overload error
Error code
- 000421 SEL1 PID overload error
- 000423 SEL1 PID reverse error
- 000424 SEL1 PID lock error
Occurrence condition
- Valve selection motor cannot operate due to large motor load
- Valve selection motor is rotating in reverse
- Valve selection motor cannot rotate
Assumed cause 
- When the motor rotates in a direction different from the rotation direction (there was a sudden load abnormality, and the motor rotated in the opposite direction due to the reaction force)
- +42V power is not supplied.
- The motor load exceeds the expected
Related parts
- Harness polarity wrong
- Valve selection motor (valve selection encoder)
- The motor load exceeds the expected
- MCU board failure
- Main Board
Troubleshooting
| Step | Confirmation and action | YES | NO |
|---|---|---|---|
| 1 | Check harness connection |
Go to step 2 | Reconnect the harness |
| 2 | Parts replacement |
Go to step 3 | End |
| 3 | Parts replacement Replace the MCU board Is the trouble phenomenon still occurring? |
Go to step 4 | End |
| 4 | Parts replacement |
Contact EPSON Local Service Representatives | End |