60213 ADF Scan Position Calibration (300dpi Single feed)
Adjust the single feed sub scaling (paper feed direction) for ADF scanning (300dpi).
The following charts are used for this adjustment.
| Chart name | Product name | Part code | Chart image |
|---|---|---|---|
ADF, CHART(J), A4-DS |
ADF, CHART(J), A4-DS |
1874105-00 |
|
Chart setting direction
Load the paper with the A side facing up and facing the paper feed slot so that the arrow is at the top.
Adjustment Procedure
- Start the service support mode.

- Select [06 Individual Adjustment].

- Select [ADF / SCN] tab.
- Select [60213 ADF Scan Position Calibration (300dpi Single feed)].
- Set the chart on the ADF tray and press [Execute].