60112 Pre-Head Sensor Correction
Corrects the luminous intensity variation of the Pre-Head Sensor.
Enter the correction value on the label attached to the Anti Static Brush Unit.
- Start the service support mode.

- Select [06 Individual Adjustment].

- Select the [Main Unit・Additional Cassette] tab.
- select [60112 Pre-Head Sensor correction].
- Open the Right Door Unit and Belt Unit, and check the correction value label.

- Enter the correction value HF and press [OK].