ADF Scan Position/ Scaling Calibration (300dpi Continuas feed)

Adjust the continuous feed sub scaling (paper feed direction) for ADF scanning (300dpi).

The following charts are used for this adjustment.

Chart name Product name Part code Chart image

ADF, CHART(J), A4-DS

ADF, CHART(J), A4-DS

1874105-00

  • Side A
  • Side B
Chart setting direction

Load the paper with the A side facing up and facing the paper feed slot so that the arrow is at the top.

Adjustment Procedure
  1. Start the service support mode.
  2. Select [06 Individual Adjustment].
  3. Select [ADF / SCN] tab.
  4. Select [60204 ADF Scan Position/ Scaling Calibration (300dpi Continuas feed)].
  5. Set the chart on the ADF tray and press [Execute].