ADF / Scanner Trouble
Image failure
| Symptom | Confirmation and action | Parts replacement / Adjustment |
|---|---|---|
| Dark lines(excluding printing from PC) |
|
If the problem persists after cleaning, replace the ADF/SCN Unit. |
| Part or the whole of the image is not read |
|
If the problem persists after treatment, replace the ADF/SCN Unit. |
| The scanned image is too faint |
|
If the problem persists after treatment, replace the ADF/SCN Unit. |
| The scanned image is skewed to the paper fed from the ADF input tray |
|
If the problem persists after treatment, replace the ADF/SCN Unit. |
Other print quality problems occurred only when copying |
|
If the problem persists after treatment, replace the ADF/SCN Unit. |
Transport Failure
| Symptom | Confirmation and action | Parts replacement / Adjustment |
|---|---|---|
| Multi-Feed | Clean the Pickup Roller, ADF (3 places). | If the problem persists after cleaning, replace the Pickup Roller, ADF |
| Manuscript fold | Check if there is any foreign substances or damage in the ADF transport path. | After cleaning the inside of the path, replace the ADF unit if any damage is found. |
| Paper jam occurs frequently in fed from the ADF input tray |
|
If the problem persists after cleaning, replace the pickup roller, separation roller. |